MG2 Planeta 50 Capsule Machine

The PLANETA is a compact, high-speed capsule filling machine designed to dose a pre-set quantity of product in hard gelatine capsules.

Less Than 100 Hours Use

• Make: MG2
• Model: Planeta 50
• Serial #: 4627
• Year of Manufacture: 2007
• Power Requirements: 460V, 60HZ, 3PH
• Nominal production speed: 6,000, 12,000, 25,000, 50,000 Capsules/hour.
• Conforms to the requirements of Directive EEC 98/37 as amended and is based on GMP (Good Manufacturing Practice) standards.
• Managed by the newly designed man/machine interface system, named MCI (Machine Control Interface).
• Dose options available: Powder, Pellets, Tablets, Microtablets

Powder Dosing Unit
One Powder Dosing Unit, complete with:
      - Motorized adjustment of the dosing chamber, compression and product layer.
      - Relevant values display on monitor
      - Self-positioning on pre-set values for different products.
      - Product maximum and minimum level detectors into hopper.

Pellet Dosing Unit

Two Pellet Dosing Units, complete with:
      - Motorized adjustment of two separate dosing chambers.
      - Relevant values display on monitor
      - Adjustments self-positioning on pre-set values for different products.
      - Product maximum and minimum level detectors into hopper.
Change parts:
0, 0L, 1, 1L, and size 3

Weight Control Option:
Nett System integrated to the capsule filler to control, in process, the quantity of the dosed product in all filled capsules. The system consists of:
      - “SWC” Statistical Weight Control System
      - Capacitive sensors to check empty and filled capsules
      - Analytical balance for capacitive sensors
      - Appliance software integrated to control cabinet computer
      - System for the automatic elimination from production of possible under-dosed, overdosed, or                  not controlled capsules
      - Immediate self-adjustment of the dosing chamber to keep the weights in compliance with the                  net weight value.